{"product_id":"12-channel-12-lead-system-24-hours-multi-language-monitoring-pc-sw-ce-fda-holter","title":"12 Channel 12 Lead Holter Monitor – 24 Hour Multi-language Recording with PC Software CE FDA","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eDynamic ECG Systems adopt a 12-lead system of international standards, which can continuously record ECG waveform for 24 hours and analyze ECG waveform by the PC software. It is applicable for use in medical institutions and communities. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e \u003cbr\u003e1)The recorder can real-time store ECG data for 24 hours. \u003cbr\u003e2)Arrhythmia analysis based on MCSSTM and TMCATM can greatly reduce doctor’s work. \u003cbr\u003e3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately and with no distortion. \u003cbr\u003e4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms. \u003cbr\u003e5)Flexible analysis channel selection function, which ensures that any channel can be selected as the main analysis channel. \u003cbr\u003e6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO\/manual analysis, more accurate in atrial fibrillation analysis. \u003cbr\u003e7)All pacemakers(such as AAI, VVI, DDD, etc.) can be analyzed by the powerful pacemaker analysis function. \u003cbr\u003e8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc. \u003cbr\u003e9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function. \u003cbr\u003e10)With analysis functions for 5-minute, 1-hour, and 24-hour heart rate variability. \u003cbr\u003e11)One-key print, convenient and fast to print the reports. \u003cbr\u003e12)Perfect case management function. \u003cbr\u003e13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help doctors comprehensively judge myocardial ischemia. \u003cbr\u003e14)The risk of sleep breath pause can be predicted by the unique \"Sleep breath pause syndrome\"analysis function. \u003cbr\u003e15)The death risk in patients with myocardial infarction can be predicted by the \"HRT\" analysis function. \u003cbr\u003e16)“T-wave alternation” is an important index to predict malignant arrhythmia and sudden cardiac death. \u003cbr\u003e17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e \u003cbr\u003eLead: standard 12-lead \u003cbr\u003eRecord time: 24-hour \u003cbr\u003ePower supply: two “AA” batteries \u003cbr\u003eInterface: USB2.0 \u003cbr\u003eSampling accuracy: 24bit \u003cbr\u003eSampling frequency: 250Hz \u003cbr\u003eDynamic range: 10mV \u003cbr\u003eInput impedance: ≥10MΩ \u003cbr\u003eCMR: ≥60dB \u003cbr\u003eGain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10% \u003cbr\u003eGain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over 24 hours. \u003cbr\u003eSystem noise: ≤50µVp-p \u003cbr\u003eMultichannel crosstalk: ≤0.2mV \u003cbr\u003eFrequency response: The amplitude response to sinusoidal signals within the frequency range of 0.05Hz to 40Hz shall be between +3dB to -3dB of the response at 5 Hz. \u003cbr\u003eMinimum measure signal: 50 µV \u003cbr\u003eWith the function in the presence of pacemaker pulses \u003cbr\u003eTiming accuracy: the overall error during 24 hours shall not exceed 30 seconds. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e \u003cbr\u003eLead cable (1 set) \u003cbr\u003eECG electrode (1 bag) \u003cbr\u003eUSB cable(1) \u003cbr\u003eBag(1) \u003cbr\u003eUser manual(1) \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePhysical characteristic\u003c\/strong\u003e \u003cbr\u003eDimension: 111mm(L) × 61mm(W) × 25mm(H) \u003cbr\u003eWeight: about 105g(without batteries) \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOptional configuration\u003c\/strong\u003e \u003cbr\u003eRefer to BOM. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e \u003cbr\u003eCE, FDA\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0633\/7390\/2073\/files\/4cd22f0b-9cec-470b-a3b5-de97870b5d8f.jpg?v=1714894139\"\u003e\u003c\/p\u003e","brand":"SWN","offers":[{"title":"TLC5000","offer_id":44966719881465,"sku":"CJZN1707211-TLC5000","price":68932.71,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0633\/7390\/2073\/files\/c6792193-4d69-4ab9-b106-d24c3260259c.jpg?v=1714894118","url":"https:\/\/www.sociableweavernest.com\/products\/12-channel-12-lead-system-24-hours-multi-language-monitoring-pc-sw-ce-fda-holter","provider":"Sociable Weaver Nest","version":"1.0","type":"link"}